Thermo Infrared Imaging Audit Services

Thermal Infrared Imaging Audits for Facilities and Electrical Systems

Heat is the first symptom of most facility failures. A Wilmes thermal imaging audit finds overheating electrical connections before they arc, wet roof insulation before the ceiling stains, and failing motors before they seize — with images and temperatures your maintenance team can act on the same week.

NFPA 70B
Recommends annual IR of electrical gear
Energized
Scanned under load, no shutdown
Same week
Report with image pairs and temperatures
Prioritized
Every finding severity-rated

What We Scan

Electrical distribution

Main switchgear, panels, disconnects, transformers, motor control centers, and busways. Loose lugs, overloaded phases, and failing breakers show as hot spots long before they fail.

Roofs

Evening scans of low-slope roofs locate wet insulation that holds daytime heat. Map the wet area, replace only what’s wet, and document the rest of the roof is dry.

Building envelope

Missing insulation, air infiltration, thermal bridging, and moisture behind walls and ceilings. Useful before and after energy retrofits.

Mechanical

Bearings, motors, pumps, belts, and compressors. Friction and misalignment show up as heat before vibration analysis catches them.

Water intrusion

Plumbing leaks, irrigation overspray into walls, and slab moisture — located without opening walls.

Post-event

After a fire, flood, or electrical incident: document damage extent and hidden moisture for the claim.

Who Uses This

  • School districts — aging electrical rooms, portable classrooms, and roofs before winter.
  • Cities and water districts — pump stations, treatment plants, civic buildings, and switchgear that can’t go down.
  • Property owners and JPAs — loss-control credit and pre-renewal documentation for the carrier.
  • Contractors — commissioning verification and warranty disputes.

Why Wilmes

Wilmes, LLC has served California school districts, JPAs, cities, water districts, and employers since 2012 — more than 100 clients. Steve Wilmes holds the ARM-P, RSSP, CPSI, SHRM-CP, and PHR credentials and has 30+ years of EHS and risk management experience. Findings are written as risk control items with severity and corrective action, not just a stack of images, so they go straight into your work-order system or AskJoy.

Related: Sign retroreflectivity audits · Loss control audits

Frequently Asked Questions

What does a thermal imaging audit find?

Overheating breakers, loose connections, and overloaded circuits in electrical panels and switchgear; wet insulation and trapped moisture in roofs; missing insulation and air leaks in building envelopes; failing bearings and motors in mechanical equipment; and hidden water intrusion in walls and ceilings.

How often should electrical equipment be scanned?

NFPA 70B recommends infrared inspection of electrical distribution equipment at least annually, and more often for critical or high-load systems. Most insurers and JPAs credit an annual program.

Does it require a shutdown?

No. Electrical scans are done with equipment energized and under load, which is when problems show. Panel covers are removed by your electrician or ours while we scan.

What’s in the report?

Thermal and visible-light image pairs for every finding, measured temperatures and delta-T, a severity rating, location, and the recommended corrective action.

Find it while it’s still a hot spot

Tell us the facility type, number of panels, and roof square footage. We’ll quote a one-time scan or an annual program.

Direct Line

Visit21415 S. Vermont Ave, Suite 9
Torrance, CA 90502
Risk Is Our Business · Wilmes, LLC Risk Control Services · CA & NV